    Lachgas-Emissionen einer Kläranlage im Vergleich zum CO2-Äquivalent

    Nitrous oxide from wastewater plants: the biology in the tank decides the climate balance

    Nitrous oxide is around 300 times more potent than CO2. It forms inside wastewater plants during normal operation, and nobody sees it. The SENTRY biofilm sensor from GIMAT makes the biology in the tank visible before emissions occur.

    When a wastewater treatment plant is judged on its climate footprint, most people look at the electricity bill for aeration. The bigger problem often sits invisibly above the tank. Nitrous oxide (N2O) forms during nitrogen removal as an intermediate and escapes into the atmosphere as soon as the reaction chain in the biology breaks down. For municipalities that have to report their climate balance, this is an item that appears in no energy audit.

    Why the biology loses its rhythm

    Nitrous oxide is a normal part of nitrogen conversion. Nitrification and denitrification produce it as an intermediate stage, and under stable conditions it is processed further. It becomes critical when the process stalls. Two triggers show up in practice again and again: sudden load peaks in the influent and a shortage of easily degradable carbon, measured as BOD or readily biodegradable COD. When the denitrifying bacteria run out of energy, the chain breaks and the greenhouse gas leaves through the surface. The effluent value can still look fine at that moment. That is what makes the situation deceptive.

    Off-gas measurement shows the result, not the cause

    Many operators have invested in gas measurement in the exhaust air over the past years. Dr. Volker Koschay, managing director of GIMAT, considers that the second step before the first: such systems are expensive, maintenance-intensive and only reveal the problem once it already exists. The SENTRY probe works in the liquid phase instead. It delivers a signal every minute on how actively the microorganisms in the tank are working. With that information, aeration and carbon dosing can be adjusted before the biology tips over.

    A natural biofilm does the measuring

    The principle needs no chemicals. Microorganisms in the wastewater settle as a biofilm on the sensor surface, exactly as they would on any other material in the tank. Degrading organic matter produces a tiny electrical current. That current is proportional to the organic load and therefore a direct measure of biological activity. No reagents are required, and neither are optical lenses or fixed cleaning intervals. Maintenance stays low and operation stays stable.

    SENTRY probe with biofilm in the aeration tank
    The SENTRY probe sits in the aeration tank. The biofilm on its surface does the measuring.

    What operators control with it

    Three things follow from the signal that matter in daily work:

    • If the denitrifiers lack carbon, the probe shows it immediately. Dosing can be corrected before nitrogen leaves as nitrous oxide instead of harmless N2.
    • During load peaks, aeration in the tanks runs feed-forward instead of reacting after the fact.
    • The system keeps running without regular cleaning cycles and without consumables.
    SENTRY dashboard with real-time values
    The dashboard shows biological activity minute by minute.

    Who is behind the technology

    The system was developed by SENTRY Water Monitoring, based in Canada. The company belongs to the US group USALCO, which works in water chemistry and the digitalisation of water processes. GIMAT Liquid Monitoring in Polling distributes the sensors as exclusive representative for the German-speaking market. For operators that means one local contact who knows the application from wastewater practice.

    SENTRY controller for the biofilm sensor
    The controller collects the probe signals and passes them to the plant control system.

    Bringing climate balance and effluent values together

    The EU has tightened requirements for wastewater plants for years, and at the same time municipalities and associations ask for reliable climate figures. Real-time process stabilisation serves both. It protects effluent values because the biology no longer runs at the edge. And it lowers the CO2 footprint because the nitrous oxide never forms. Operators who also run aeration on demand save electricity on top.

    Start with a pilot, then decide

    Technical data and field examples for the SENTRY BOD and toxicity sensor are available on the GIMAT product page. Anyone who wants to test the sensor at their own plant gets support with planning a pilot project by e-mail at info@gimat.de or by phone on +49 881 628-0. The best starting point is a plant that regularly struggles with load peaks. That is where the benefit shows fastest.

    SENTRY sensor in the influent of a wastewater plant
    The influent shows first what load the biology will face.
    https://www.gimat.de/wp-content/uploads/2026/11/sentry-lachgas-co2-aequivalent.webp 466 699 heartbit /wp-content/uploads/2016/12/GIMAT_Logo.png heartbit2026-11-19 09:00:002026-11-19 17:30:49Nitrous oxide from wastewater plants: the biology in the tank decides the climate balance
    Prozessrefraktometer ATAGO CM-800

    Brix under control: how inline refractometers cut waste and rinse water in beverage production

    Every sip should taste like the one before. At the same time, every filling line runs under cost pressure. Inline refractometers from ATAGO, integrated by GIMAT, measure Brix and concentration directly in the pipe instead of sending samples to the lab.

    Fruit juice, energy drinks, flavoured water or a syrup for food service: modern recipes no longer tolerate deviation. Sweetness shapes the taste, and taste shapes brand loyalty. Most soft drinks sit at around 10 grams of total sugar per 100 millilitres, fruit sugar and added sugar combined. That is the figure quality assurance watches, and in the lab it can only be checked by sampling. Between two samples sit hundreds of litres that have long been bottled.

    Blending: holding the recipe when the fruit varies

    The moment raw material and water meet in the mixing plant, a look into the pipe pays off. If the Brix value drifts from target, volumes can be corrected while the batch is still in the tank. With juice this is the decisive point: a refractometer captures total sugar content regardless of where it comes from. Apples from different orchards and ripeness stages bring different sweetness. That natural spread can be balanced through sugar addition until the target of, say, 10 % Brix is reached. Without that control a second error tends to slip through: if sugar drops while acid dosing continues unchanged, the taste turns sour. The customer notices, the lab often only at the next sample.

    Control room of a beverage filling line
    Brix values from the line arrive in the filling control room.

    Product changes: the border between two products

    More varieties and more flavours mean more product changes per shift on modern filling lines. Before bottling and when switching between two batches, the refractometer acts as a guard in the piping system. It detects within seconds where the new batch has replaced the old one. Mix-ups drop out, and far less product is lost at the interface. With expensive concentrates and small batches, that pays back quickly.

    CIP: when the line is really clean

    After production comes cleaning, and that is often where the largest savings sit. During cleaning in place, the same sensor monitors the concentration of caustic soda or acid cleaner. Underdosing endangers hygiene, overdosing costs chemicals and wastewater load. The final rinse is where it gets interesting. A cleaning solution typically reads around 1.5 to 2.5 % Brix, pure drinking water reads 0.0 % Brix. Lines without sensors rinse far longer than necessary for safety reasons. Once the refractometer reports 0.0 % Brix, the line is verifiably free and the next batch can start. That saves drinking water, energy and wastewater volume, and it lowers the COD load that municipal treatment plants bill for.

    Phases of CIP cleaning
    The final rinse ends as soon as the refractometer reports 0.0 % Brix.

    Why optics measure more robustly than density here

    Density methods reach their limits with pulp, turbidity and micro air bubbles, because these distort the reading. The ATAGO process refractometers work optically on a sapphire prism and remain unaffected. Automatic temperature compensation (ATC) balances fluctuating process temperatures, up to hot filling and CIP conditions. The compact CM-Base covers straightforward tasks, while the high-resolution CM-800α comes in when space is tight.

    From the sensor to the PLC

    Sensors only deliver value once they reach the control system. GIMAT is an ATAGO distributor and service centre and works as a system integrator: selecting the right device, designing the measuring point, integrating it into the PLC, logging measurement and cleaning values. For quality managers the last point matters most. Complete batch documentation makes evidence for IFS Food or HACCP audits considerably easier, because the values come from the plant itself rather than from handwritten lists.

    What production managers should check first

    Three questions usually clarify the need: how often does the product change, how much product is lost at the interfaces, and how long does the line rinse after cleaning? Where one of these answers is uncomfortable, measuring is worth it. Details on the devices are on the product pages for the CM-800 α process refractometer and the CM-BASE α. For help choosing the right measuring point, the application engineers advise without obligation, by phone or on site: info@gimat.de.

    https://www.gimat.de/wp-content/uploads/2026/11/atago-cm-800-getraenkeindustrie-1.webp 466 699 heartbit /wp-content/uploads/2016/12/GIMAT_Logo.png heartbit2026-11-18 09:00:002026-11-19 17:30:51Brix under control: how inline refractometers cut waste and rinse water in beverage production

    Publikationen

    Archive

    • November 2026
    • August 2026
    • July 2026
    • March 2026
    • September 2025
    • August 2025
    • July 2025
    • June 2025
    • May 2025
    • April 2025
    • March 2025
    • February 2025
    • December 2024
    • November 2024
    • October 2024
    • October 2020
    • September 2019
    • May 2019
    • January 2019
    • October 2018
    • May 2017
    • February 2017
    • January 2016

    Service

    • Order accessories
    • Customer service request
    • Request brochure

    Contact

    GIMAT GmbH
    Liquid Monitoring

    Obermühlstrasse 70
    82398 Polling
    Germany

    Phone: +49 (0)881 628-10
    Fax: +49 (0)881 628-15
    e-Mail: info@gimat.de

    International GIMAT Agencies

    Are you interested in collaborating with GIMAT? We are looking for agents the world over with expertise in the river water, industrial water and waste water market. If you are interested, please contact us.

    Search

    Search Search

    Share this page

    •  
    © 2025 GIMAT GmbH. All rights reserved.
      • Contact
      • AGB
      • Cookie policy
      • Privacy Policy
      • Imprint
      • Webdesign PollingWebdesign Polling – Homepageerstellung, Online-Shops, Internetprogrammierung, Suchmaschinenoptimierung (SEO), Webtexterstellung, CMS, Pflege und Wartung von Webseiten – Polling, Weilheim-Schongau, München
      Scroll to top Scroll to top Scroll to top